Zoom
Zoom
Zoom
* Image may not reflect selected features
8516-187

TG611-17 (4000 CCW)

4035 DROOP, CCW, SS, OSTD, ATEX

An API611 steam turbine mechanical-hydraulic governor with screw speed set range of 2400-4000 rpm, rated speed-droop at 4035 rpm at 2°, with a counterclockwise drive shaft rotation, and integrated overspeed test device (OTSD) for ATEX locations. The governor’s 23.7 N m (17.5 ft-lb) counterclockwise rotary output terminal shaft connects to the turbine’s governor valve to control turbine inlet steam flow.
Product Type

About 8516-187

Steam Turbine Governor|Web Store

  • Application Notes
  • Brochure
  • Product Specification
  • Software Manual
  • Technical Manual
  • Software
FEATURES & FUNCTIONALITY

An API611 steam turbine mechanical-hydraulic governor with screw speed set range of 2400-4000 rpm, rated speed-droop at 4035 rpm at 2°, with a counterclockwise drive shaft rotation, and integrated overspeed test device (OTSD) for ATEX locations.  The governor’s 23.7 N m (17.5 ft-lb) counterclockwise rotary output terminal shaft connects to the turbine’s governor valve to control turbine inlet steam flow.

Features & Functions:

The TG611-17 die-cast aluminum mechanical-hydraulic speed droop governor controls API611 steam turbines driving pumps, compressors, or generators where isochronous (constant-speed) operations is not required.  The governor controls turbine speed by sensing turbine rotor speed via the input drive shaft, comparing this speed to an internal speed set point, then using a rotary output terminal shaft connected to the turbine’s governor valve control turbine inlet steam flow. 

This self-contained governor utilizes an integrated driveshaft-driven ball head assembly to sense turbine speed, and an integrated driveshaft-driven oil pump to create the necessary output force to move/control the turbine’s governor valve.  The TG611-17 governor includes a special Overspeed Test Device (OSTD), allowing controlled and safe turbine overspeed trip testing initiated from any speed setting in a safe matter.

Same as:  8516-045 plus Integrated Overspeed Test Device

Applications:

Where isochronous (constant-speed) operation is not required, the TG611-17 drives steam turbines in:

  • Pumps
  • Compressors/Turboexpanders
  • Force and Inlet Draft Fans
  • Generators

Features:

  • API611 compliant
  • Low cost
  • Speed droop control
  • Counterclockwise drive shaft
  • Integral overspeed test device (OTSD)
  • Weatherproof construction
  • Self-contained sump
  • NEMA "A" speed control
  • 23.7 N m (17.5 ft-lb) outputs
  • Designed for harsh environments
  • Certified for HAZLOC and ATEX locations

How can we help?

Download Manuals

Downloads & Manuals

Software and information is available on Woodward.com.

Product History Lookup

Product History Lookup

Look up your Woodward product by serial number.

Woodward Support

Support

We're here for you, call, email, or open a helpdesk ticket.

 

Download

Product Specification
Name
Item Number
Language
TG611-13/-17 GOVERNOR WITH OVERSPEED TEST DEVICE
03368
English
Technical Manual
Name
Item Number
Language
TG-13/TG-17 AND TG611-13/TG611-17 GOVERNORS
04042
English
OILS FOR HYDRAULIC CONTROLS
25071
English
COMMERCIAL PRESERVATION PACKAGING FOR STORAGE OF MECHANICAL-HYDRAULIC CONTROLS
25075
English
COMMERCIAL PRESERV PKG FOR STORAGE OF MECH-HYDR CONTROLS
JP25075
Japanese
TG-13 AND TG-17 GOVERNORS
JA04042
Japanese
TG-13 AND TG-17 GOVERNORS
CH04042
Chinese