Home 9927-1799_A

GAP Programmer –old versions

9927-1799_A.exe

This Version Will Only Support MCU, PCMHD and ECM3 Platforms For all other platforms use Coder 5.02-2. This installation contains
  • Coder 5.02-1
  • GAP 5.02 Template
  • VxWorks Libraries
  • OpWgx Libraries
  • GNU support
  • GAP 2.18C Editor
  • SOS 3.5
  • AppManager 2.10
  • Control Assistant 3.10
  • Ladder Logic 2.10
The Coder software tool is designed to support the creation and compiling of GAP applications for use in MCU, PCMHD and ECM3 Woodward product lines. Any other product line can use Coder 5.02-2. WARNING: This version GAP/Coder is only compatible with GAP 2.18C or above WARNING: This version GAP/Coder is only compatible with SOS 3.5 or above WARNING: This version GAP/Coder is only compatible with Toolkit 3.3-2 or above

WARNING:
If installing an older coder version on a PC with a newer version, it is possible to overwrite the Hex2Scpt.exe file with an older version. This might cause the newer coder version to fail when generating ".scp" files. Newer versions of Hex2Scpt.exe are backward compatible, so this problem can be addressed by re-installing the latest Hex2Scpt.exe file from the Woodward website (use "Hex2Scpt" as the search string) after installing an older version.
This is a potential issue for coder installations like this one that are not platform-specific and may support controls which use the .scp file format.

What’s New in 5.02-1
  • DISABLED ALL NON WGX (565 processor-based) CONTROLS
  • Init Event Manager Bug was fixed
What’s New in 5.02-0
  • Additional RAM: 4K extra bytes were made available on the PCMHD
  • PCMHD EEprom health: To extend the life of the EEprom on the PCMHD, an AUTO_SAVE field was added to the PCM_STATUS block.
  • Event Manager / DM Mil Enhancements for more rigorous compliance with OBD standards:
    • Events have a new attribute, “MIL”
    • It is possible to select either timer format or date/time format for HMI time values (supported in Toolkit 3.3 update 2 and later)
  • J1939 requests for multi-packet messages are now responded to correctly for both global and specific destination addresses
  • New start permissive for VxWorks controls
  • Support for longer Category and Blocknames in GAP 3.x (20 chars each). Requires GAP 3.x editor

System Requirements:

Installation Instructions:

  1. The first step in installing the GAP Programmer is to download the file from this page. This file is an installation program that will step you through the installation process.
  2. After downloading this file, run it and follow the instructions on the setup dialogs.

Download:

Item Name Version Size
9927-1799
GAP Programmer –old versions
A
71.44 MB