Woodward

HighPROTEC-2 – Electrical Protection Made Simple

    HighPROTEC
     

    HighPROTEC – the Easy Solution for Medium Voltage Applications

    Short ordering codes, commissioning support features, flexible hardware.  Straight off the shelf and right into your MV switchboard! That's the simplistic beauty of our new HighPROTEC protection devices!

    New as of Release 3.4:

    • Compatibility with “FNN 2015”
      (Forum Netztechnik/Netzbetrieb VDE/FNN, FNN-Hinweis „Anforderungen an digitale Schutzeinrichtungen“ (2015). Details see Declaration of Conformity.)
    • IT Security (Menu for the activation of BDEW-Whitepaper-compliant security settings (e. g. hardening of interfaces)

     

    HighPROTEC, the next generation of protection relays from Woodward, makes protecting medium voltage feeders, generators, transformers, and motors simple, reducing effort and cost.  It can be easily configured for specific application requirements and accepts 0‒800 VAC and 1A / 5A inputs, a wide range of supply power, communication protocols (DNP3.0, IEC 61850, IEC 60870-103, Modbus, Profibus), and menus in seven different languages.  It displays system connections, operating values, and messages/alarms/fault data – making it easy to use.  Worldwide certifications include CE, UL, CSA, EAC, and marine certifications.

    • Easy to use (individual configurable devices with adaptable menu structure, plausibility check, ANSI menu structure can be turned on and off …
    • Reduces your maintenance and commissioning efforts (Integrated fault Simulator,…)
    • Highest hardware flexibility (1A / 5A inputs, wide range power supply,...)
    • No hidden costs: Protection packages inclusive. The operating software Smart view can be downloaded and installed without extra charge.
    • 8 languages selectable within the relay (English / German / Spanish / Russian / Polish / Portuguese / French / Romanian)
    • Various communication protocols (IEC 61850, Modbus, DNP3, Profibus, IEC 60870‑5‑103)
    • World wide certifications like CE, UL, CSA, EAC, Marine,...
    • Covers world-wide interconnection standards like IEEE1547, BDEW, G59

    MCA4

    Medium Voltage Feeder Protection MCA4

    Directional OC&EF Protection – Control of up to 6 Switchgears

    MCA4 is the ideal directional feeder protection for industrial and utility distribution networks. Integrated interconnection / grid code package. Large control capacity for switchgear. Very large protection package (reclosing, load shedding, load restoration, demand management, monitoring functions,...)

    ANSI: 50, 51, 67, 51C, 51V, 50N, 51N, 67N, 46, 49, 27, 59, 59N, 81U/O, 60FL, 79, 86, 50BF, 74TC , 81R, 78, 47, 60FL, 60L, 32F, 25, 37F, 32Q, 37Q, 37QR, 32S, 37S, 37R, 55, 51C, LVRT , Q->V, UFLS

     

    MRA4

    Medium Voltage Directional Feeder Protection MRA4

    Directional Overcurrent & Ground (Earth) Fault Protection – Interconnection Specialist

    MRA4 is ideal for industrial and utility directional feeder applications. Very large protection package (reclosing, load shedding, load restoration, demand management, monitoring functions,... )

    ANSI: 50, 51, 67, 51C, 51V, 50N, 51N, 67N, 46, 49, 27, 59, 59N, 81U/O, 60FL, 79, 86, 50BF, 74TC , 81R, 78, 47, 60FL, 60L, 32F, 25, 37F, 32Q, 37Q, 37QR, 32S, 37S, 37R, 55, 51C, LVRT , Q->V, UFLS

     

    MRI4

    Non-Directional Overcurrent Medium Voltage Protection Relay MRI4

    Overcurrent and Earth Fault Protection

    MRI4 is an overcurrent and earth fault relay, tailored for industrial and utility applications with recloser and breaker wear functionality.

    ANSI: 50, 51, 50N, 51N, 46, 49, 60L, 79, 86, 50BF, 74TC

     

    MRU4

    Medium Voltage Decoupling Relay MRU4

    Voltage and Frequency Protection

    MRU4 can be used in industrial and utility distribution systems, to supervise voltage and frequency fluctuations, for monitoring and for load shedding and load restoration.

    ANSI : 27, 59, 59N, 81U/O, 60FL, 47, 86, 74TC , 81R, 78, ROCOF, 25

     

    MRMV4

    Medium Voltage Motor Protection Relay MRMV4

    Motor Protection with Voltage

    The MRMV4 is designed for motor protection applications and has a large package of monitoring and protection functions, such as motor star-up, thermal overload, incomplete start-up sequence. Voltage, power and frequency are supervised as well. The motor temperature can be monitored via an external sensor box (URTD).

    ANSI : 46, 49M, 49R, 49S, 50J, 37, 50, 51, 50N, 51N, 50Ns, 51Ns, 27, 59, 59N, 47, 32, 55, 81U/O, 81R, 78, 60FL, 86, 50BF, 74TC , 38

     

    MRM4

    Medium Voltage Motor Protection MRM4

    Motor Protection

    The MRM4 is designed for the protection of motors. All the protection functions are based on current. The device offers motor protection functions, such as motor star-up and incomplete start-up sequence.

    ANSI : 46, 49M, 49R, 49S, 50J, 37, 50, 51, 50N, 51N, 60L, 86, 50BF, 74TC

     

    MCDTV4

    Medium Voltage Power Transformer Protection MCDTV4

    Transformer Differential Protection – 2 Windings

    The MCDTV4 is designed to protect 2 winding power transformer in substations, distribution and generator applications with a very comprehensive protection package like phase, restricted earth fault, inrush detection, and monitoring functions including grid interconnection and control functionality up to 6 switchgears.

    ANSI : 87T, 87N (64RE F), 24, 50, 51, 67, 51V, 51C, 50N, 51N, 67N, 50Ns, 51Ns, 67Ns, 46, 49, 27, 59, 59N, 81U/O, 81R, 78, 47, 32, 55, 60FL, 86, 50BF, 74TC , 25, 37, LVRT , Q->V, UFLS

     

    MRDT4

    Medium Voltage Transformer Differential Protection Relay MRDT4

    Transformer Differential Protection – 2 Windings

    MRDT4 transformer phase and earth fault differential relay is designed to protect two winding transformers in distribution, substation and generation systems. The relay can also be used as a generator and power step up transformer differential protection and also incorporates many backup protection functions.

    ANSI : 50, 51, 50N, 51N, 46, 49T, 60FL, 86, 50BF, 74TC , 60L, 64RE F, 87G, 87T

     

    MCDGV4

    Medium Voltage Generator Protection MCDGV4

    Generator Differential Protection

    The high precision generator differential protection relay MCDGV4 is designed to protect utilities and industrial generators. The step-up transformer can be easily integrated into the protection (Block Protection) without any extra charge. In addition to the differential protection package and out-of-step protection, the device offers a broad interconnection package as well as full packages for phase, earth, voltage, frequency, distance (backup), and power protection.

    New as of Release 3.4: Phase distance (backup) protection, Power Swing Blocking, Load Blinder, Out of Step Tripping (Pole-Slip protection).

    ANSI : 87G, 87GT , 87N (64RE F), 21P, 68, 78, 24, 40, 59TN /27TN , 50, 51, 67, 51V, 51C, 50N, 51N, 67N, 50Ns, 51Ns, 67Ns, 46, 49, 27, 59, 59N, 81U/O, 81R, 78, 47, 32, 55, 60FL, 86, 50BF, 74TC, 25, 37, LVRT , Q->V

     

    MCDLV4

    Line Differential Protection Relay MCDLV4

    Cable / Line Differential Protection

    The MCDLV4 is designed to protect cables and lines up to 24 km. There can even be an in-zone transformer within the line to be protected. In addition, it comes with a very comprehensive protection package like phase, restricted earth fault, inrush detection, and monitoring functions including grid interconnection and control functionality up to 6 switchgears.

    ANSI: 87L, 87T, 50P, 51P, 67P, 51C, 51V, 51Q, 46, 49, Inrush, 50N/51N, 67N, 27, 59, 47, 81U/O, 81R, 78, 25/59N, 79, 32, 37, 55, 27(t,AR) 25, 24, 50BF, 74TC, 60FL, 60L

     

    1. Log in here

    2. Click!

     

    HighPROTEC Quick Start Guide

     DOK-QS-HPT-2

     DE 

     EN 

      

      

      

      

      

    Quick Start Guide

     download manual 

     download manual 

     

     

     

     

     

    Feeder

    Manuals 

     DE 

     EN 

     ES 

     FR 

     PL 

     PT 

     RU 

    MRA4 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

    MCA4 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

    MRI4 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     

     Flyer 

     DE 

     EN 

     ES 

     FR 

     PL 

     PT 

     RU 

    MRA4 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

    MCA4 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

    MRI4 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     


    Line Differential

     Manuals 

     DE 

     EN 

     ES 

     FR 

     PL 

     PT 

     RU 

    MCDLV4

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     

     Flyer 

     DE 

     EN 

     ES 

     FR 

     PL 

     PT 

     RU 

    MCDLV4 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     

    Transformer

    Manuals 

     DE 

     EN 

     ES 

     FR 

     PL 

     PT 

     RU 

    MCDTV4 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

    MRDT4 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     

     Flyer 

     DE 

     EN 

     ES 

     FR 

     PL 

     PT 

     RU 

    MCDTV4 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

    MRDT4 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     

    Generator

     Manuals 

     DE 

     EN 

     ES 

     FR 

     PL 

     PT 

     RU 

    MCDGV4 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     

     Flyer 

     DE 

     EN 

     ES 

     FR 

     PL 

     PT 

     RU 

    MCDGV4 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     

    Motor

     Manuals 

     DE 

     EN 

     ES 

     FR 

     PL 

     PT 

     RU 

    MRMV4 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

    MRM4 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     

     Flyer 

     DE 

     EN 

     ES 

     FR 

     PL 

     PT 

     RU 

    MRMV4 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

    MRM4 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     

    Voltage / Mains Protection

     Manuals 

     DE 

     EN 

     ES 

     FR 

     PL 

     PT 

     RU 

    MRU4 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     download manual 

     

     Flyer 

     DE 

     EN 

     ES 

     FR 

     PL 

     PT 

     RU 

    MRU4 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     download product specification 

     

    HighPROTEC Services

    HPTCON

     

    ↑ ↑

    Creating the protection configuration in house according to customer data based on check lists per variation and device type.

    Programming of the device configuration in house is included.

    0 1

    Creating the protection configuration, logic and single-line in house.

    The configuration is done after customer clarification according to customer data, based per variation and device type.

    Programming of the device configuration in house is included.

    0 2

    Programming of the device configuration per device in house.

    0 3

     

    Setting and Analyzing Software Smart view

    Smart view can be directly downloaded and installed.

    (No special ordering or registration required.)

     

     

    HighPROTEC Communication and Accessories

    COMRS232Nullm

     

    RS 232 zero modem cable with Handshake (3 m)

     

    Cable for PC – device communication

    (No supply voltage required.)

     

     

    USB2RS232ADAP

     

    Interface converter

     

    from USB 2.0 to RS232 (without galvanic isolation)

    (No supply voltage required.)

     

     

    5450-1946

     

    Connection cable – Smart view to protection device

     

    Standard USB to 5-pole [USB-B Mini Male 1.8 m (EDS)]

     

     

    HPTDF1

     

    HighPROTEC distance frame

    Frame for B1 housing 60 mm depth

    1

    Frame for B2 housing 60 mm depth

    2

     

    URTD

    Universal Resistor Temperature Box (for HighPROTEC devices)

    ↑ ↑

    Up to 12 sensors, PT100, Ni100, Ni120, Cu10, 48-240 VAC / 48-250 VDC

    0 1

    Up to 12 sensors, PT100, Ni100, Ni120, Cu10, 24- 48 VDC

    0 2

     

    HPTURTDCON

    Fiber optic cable URDT

    The fibre optic cable is necessary to connect the URDT box with a HighPROTEC device.

    ↑ ↑ ↑

    Fibre optic cable 5 m

    5 M

    Fibre optic cable 10 m

    10 M

    Fibre optic cable 25 m

    25 M

     

    HPTTERMKIT

     

    Terminal kits HighPROTEC for pre wiring

    For devices MRI4 or MRM4

    1

    For devices MRU4

    2

    For devices MRA4D, MRMV4A or MCA4D

    3

    For devices MRDT4

    4

    For devices MCDGV4A, MCDGV4B, MCDTV4A or MCDTV4B

    5

     

    HPTCTCON1

     

    Kit – HPT CT Socket

     

    Current Transformer Terminals Socket for HighPROTEC

     

     

    HPTCTBLOCK1

     

    Terminal for Current Measurement

     

    For devices MRI4, MRM4, MRMV4, MRA4, MCA4, MCDTV4, MRDT4 or MCDGV4

     

     

    3061-2866

     

    Please use the PDF template on the product CD for LED text information

     

    Transparent Front Foil for Inserts

     

     

    CSPHPTADAP

     

    Mounting Plate

     

    Mounting plate door CSP to HPT

     

     

    Explore our product lines

    HighTech Line

    High Tech Line

    These relays combine well-proven technology and easy handling.

    Learn More

     

    Professional Line

    Professional Line

    Comprehensive protective functions and a competitive price performance ratio are the hallmarks of these relays.

    Learn More

     

    WI Line

    WI Line

    All relays from this line are self-powered time overcurrent relays, i.e. they take their energy from the current transformers.

    Learn More

     

    Basic Line

    Basic Line

    The right choice for low voltage applications.

    Learn More